Hybrid Power Factor Correction Panelr

View More Contact us

Benefits

  • - Performance of Active with cost effectiveness of passive
  • - Compliance with prescribed harmonic limits - No penalty
  • - Unity Power Factor - higher savings
  • - Reduced energy (kVAh) charges - higher savings
  • - Reduced peak demand charges - higher savings
  • - Reduced fuel consumption in generators - higher savings
  • - Ultra fast compensation - effective with fast fluctuating load
  • - Proven performance on welding
  • - Optimum capacity utilization of electrical infrastructure
  • - Optimum capacity utilization of backup generators
  • - Improved voltage profile
  • - Reduced risk of transformer failure - higher uptime
  • - Reduced risk of equipment failure - higher uptime
  • - Increased operational reliability - higher uptime
  • - Compact footprint
  • - Indigenous design, low maintenance and prompt service

Features

  • - Fast 32 bit digital signal processor
  • - Synchronous Rotating Frame Principal for best performance
  • - Ultra fast compensation
  • - Proven performance on welding
  • - Selective Harmonic compensation
  • - Step-less Reactive Power Compensation
  • - Negative Sequence Compensation (load balancing)
  • - Zero Sequence Compensation (neutral compensation)
  • - 15 possible Priority Selection settings for maximum flexibility
  • - Smart auto foldback to avoid over loading of filter
  • - 7" touch screen display
  • - Ethernet based remote monitoring
  • - MODBUS RTU, USB, SD Card
  • - Internal CAN Communication
  • - Closed Loop & Open Loop operation
  • - Operator Activity Log
  • - >1,00,000 time stamped events can be logged in internal NAND memory

Technical Specifications

  • Model: p2p-415-hypfc3/p2p-415-hypfc4
  • Network Voltage: 415Urms +10%/-15%
  • Connection: 3P/4W / 4P/4W
  • Grid Frequency: 50Hz +/-5% (60Hz available on request)
  • Reactive Lag Compensation : Full
  • Reactive Lead Compensation: Limited
  • Harmonic Compensation: Limited
  • Harmonic Filtering: 2nd - 25th order
  • Individual Harmonic Selection: Yes
  • Negative Sequence Compensation: Limited
  • Zero Sequence Compensation: NA / Yes (Limited)
  • Compensation: Closed Loop
  • Reaction Time: < 150 micro seconds
  • Filter Consumption: < 2.0% of rated capacity (typical)
  • CT Specifications: ratio based on peak load | 0.5 class or better | 15VA or more
  • Standards: IEEE 519-1992 harmonic standards

USER INTERFACE

  • Interface: 7" touch screen
  • Remote Interface: Ethernet, MODBUS RTU
  • Configuration Settings: Through user interface & USB key

ENVIRONMENT

  • Protection Class: IP41 (Higher on request)
  • Operating Temperature: upto 45 degrees with adequate ventilation (upto 55 degrees with derating)
  • Operating Environment: Indoor, Dust Free
  • Relative Humidity: Maximum 95% (non condensing)
  • Altitude: Upto 1000m
Lets's work together

Ready to help you!

We're here to help and answer any question you might have.

How can we help you?






Scroll