{"id":151,"date":"2026-11-19T06:23:00","date_gmt":"2026-11-19T06:23:00","guid":{"rendered":"https:\/\/www.p2power.com\/featured-insights\/?p=151"},"modified":"2026-11-20T05:15:10","modified_gmt":"2026-11-20T05:15:10","slug":"detuned-reactor","status":"publish","type":"post","link":"https:\/\/www.p2power.com\/featured-insights\/?p=151","title":{"rendered":"Detuned Reactor"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Working, Benefits and Industrial Applications<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Harmonic distortion is one of the most common power quality challenges faced by modern industrial facilities. Non-linear electrical loads such as variable frequency drives (VFDs), UPS systems, rectifiers, and other power electronic equipment generate harmonics that can affect the performance, reliability, and efficiency of electrical networks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If left unmanaged, harmonics can lead to transformer overheating, increased electrical losses, capacitor failures, motor vibrations, equipment malfunction, and reduced power factor correction system performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Detuned Reactor<\/strong> is an effective solution for protecting capacitor banks against harmonic-related issues and improving the reliability of electrical compensation systems. It is widely used in industrial power factor correction applications where harmonic distortion is a concern.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Are Harmonics in an Electrical Power System?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In a standard electrical distribution network, the supply voltage operates at a fundamental frequency of 50 Hz in India and several other countries, while some countries use 60 Hz. Ideally, the voltage and current waveforms should be sinusoidal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, modern electrical equipment containing semiconductor-based components often draws non-sinusoidal current. These non-linear loads introduce additional frequency components into the electrical system, known as <strong>harmonics<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example, the 3rd, 5th, 7th, 11th, and 13th harmonics are commonly observed in industrial power systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Common sources of harmonic distortion include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Variable Frequency Drives (VFDs)<\/li>\n\n\n\n<li>UPS systems and battery chargers<\/li>\n\n\n\n<li>Rectifiers and converters<\/li>\n\n\n\n<li>Welding machines<\/li>\n\n\n\n<li>LED lighting systems<\/li>\n\n\n\n<li>Switching power supplies<\/li>\n\n\n\n<li>Industrial automation equipment<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Effects of Harmonics on Electrical Systems<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Excessive harmonic distortion can create several operational and financial challenges, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Capacitor Bank Failure:<\/strong> Harmonics can increase capacitor current and cause overheating, insulation deterioration, and premature failure.<\/li>\n\n\n\n<li><strong>Transformer Overheating:<\/strong> Additional harmonic currents increase electrical losses and operating temperatures.<\/li>\n\n\n\n<li><strong>Motor Performance Issues:<\/strong> Harmonics can cause vibration, additional heating, torque pulsations, and reduced efficiency.<\/li>\n\n\n\n<li><strong>Circuit Breaker Malfunction:<\/strong> Harmonic currents may contribute to unexpected tripping and protection system issues.<\/li>\n\n\n\n<li><strong>Increased Power Losses:<\/strong> Harmonic distortion increases losses throughout electrical distribution networks.<\/li>\n\n\n\n<li><strong>Equipment Malfunction:<\/strong> Sensitive electronic and control equipment may experience operational disturbances.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Managing harmonics is therefore essential for maintaining electrical reliability, equipment life, and overall power quality.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is a Detuned Reactor Harmonic Filter?<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.p2power.com\/featured-insights\/wp-content\/uploads\/2026\/11\/apfc-power-factor-correction-done-1024x768.jpg\" alt=\"APFC Panel\" class=\"wp-image-153\" srcset=\"https:\/\/www.p2power.com\/featured-insights\/wp-content\/uploads\/2026\/11\/apfc-power-factor-correction-done-1024x768.jpg 1024w, https:\/\/www.p2power.com\/featured-insights\/wp-content\/uploads\/2026\/11\/apfc-power-factor-correction-done-768x576.jpg 768w, https:\/\/www.p2power.com\/featured-insights\/wp-content\/uploads\/2026\/11\/apfc-power-factor-correction-done-300x225.jpg 300w, https:\/\/www.p2power.com\/featured-insights\/wp-content\/uploads\/2026\/11\/apfc-power-factor-correction-done-1536x1152.jpg 1536w, https:\/\/www.p2power.com\/featured-insights\/wp-content\/uploads\/2026\/11\/apfc-power-factor-correction-done.jpg 1600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">APFC Panel<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong><a href=\"https:\/\/www.p2power.com\/detuned-reactor\/\" data-type=\"link\" data-id=\"https:\/\/www.p2power.com\/detuned-reactor\/\">Detuned Reactor<\/a><\/strong> is a passive harmonic mitigation arrangement that combines a series reactor (inductor) with a power factor correction capacitor bank.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The reactor is connected in series with the capacitor to create a detuned circuit. This arrangement shifts the resonant frequency of the capacitor-reactor combination below the dominant harmonic frequencies present in the electrical system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By selecting an appropriate detuning factor, the system helps prevent harmonic resonance, limits excessive harmonic current flow into capacitor banks, and protects capacitors against harmonic-related overloading.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned reactors are commonly integrated into <a href=\"https:\/\/www.p2power.com\/apfc-rtpfc-panel\/\" data-type=\"link\" data-id=\"https:\/\/www.p2power.com\/apfc-rtpfc-panel\/\">Automatic Power Factor Correction (APFC)<\/a> panels and other capacitor-based compensation systems.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How Does a Detuned Reactor Work?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A detuned reactor works by changing the electrical characteristics of a capacitor bank through series inductance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When a capacitor bank operates in a harmonic-rich electrical network, it can interact with the system inductance and create parallel or series resonance conditions. Such conditions may amplify harmonic currents and increase the risk of capacitor failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A detuned reactor helps minimise this risk by shifting the resonant frequency of the capacitor-reactor combination away from the dominant harmonic frequencies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The basic operating process involves:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Series Connection:<\/strong> The reactor is connected in series with the capacitor bank.<\/li>\n\n\n\n<li><strong>Frequency Detuning:<\/strong> The reactor changes the resonant frequency of the capacitor-reactor circuit.<\/li>\n\n\n\n<li><strong>Resonance Prevention:<\/strong> The detuned arrangement reduces the risk of resonance with dominant harmonic frequencies.<\/li>\n\n\n\n<li><strong>Capacitor Protection:<\/strong> It helps limit harmonic-related overloading and improves capacitor bank reliability.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">The selection of the reactor rating and detuning percentage depends on the system voltage, capacitor rating, harmonic spectrum, and network conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Types of Harmonic Filters: Passive and Active<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Harmonic mitigation solutions are generally classified into passive and active harmonic filters.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Passive Harmonic Filters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Passive harmonic filters use combinations of inductors and capacitors to provide a low-impedance path for selected harmonic frequencies or to modify the network&#8217;s frequency response.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned reactors are also used with capacitor banks to reduce the risk of harmonic resonance and protect power factor correction equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key applications:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial APFC panels<\/li>\n\n\n\n<li>Capacitor bank protection<\/li>\n\n\n\n<li>Harmonic mitigation in electrical distribution systems<\/li>\n\n\n\n<li>Industrial facilities with non-linear loads<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. Active Harmonic Filters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.p2power.com\/active-power-filter\/\" data-type=\"link\" data-id=\"https:\/\/www.p2power.com\/active-power-filter\/\">Active Harmonic Filters (AHFs)<\/a> use advanced power electronics and real-time control systems to detect harmonic currents generated by non-linear loads.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The filter injects compensating currents in opposition to the unwanted harmonic components, reducing harmonic distortion in the electrical network.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key advantages:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dynamic harmonic compensation<\/li>\n\n\n\n<li>Compensation of multiple harmonic orders<\/li>\n\n\n\n<li>Adaptability to changing load conditions<\/li>\n\n\n\n<li>Improved electrical power quality<\/li>\n\n\n\n<li>Support for reactive power compensation, depending on the system configuration<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Unlike detuned reactors, active harmonic filters can dynamically compensate for varying harmonic loads.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Role of Detuned Reactors in Power Factor Correction Systems<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Power Factor Correction (PFC)<\/strong> systems are widely used in industrial facilities to improve <strong>power factor<\/strong> and reduce reactive power demand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, when capacitor banks operate in networks containing significant harmonic distortion, they may experience excessive current, overheating, and premature failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Installing detuned reactors in series with capacitor banks helps protect the compensation system from harmonic resonance and excessive harmonic loading.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why Are Detuned Reactors Important for APFC Panels?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned reactors offer several benefits in industrial power factor correction applications:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Improved Capacitor Protection:<\/strong> Helps prevent capacitor bank damage caused by harmonic resonance.<\/li>\n\n\n\n<li><strong>Reduced Resonance Risk:<\/strong> Shifts the resonant frequency of the capacitor-reactor circuit.<\/li>\n\n\n\n<li><strong>Enhanced System Reliability:<\/strong> Supports more stable operation of APFC panels.<\/li>\n\n\n\n<li><strong>Lower Maintenance Requirements:<\/strong> Helps reduce harmonic-related capacitor failures and replacement frequency.<\/li>\n\n\n\n<li><strong>Improved Power Quality:<\/strong> Supports reliable operation of capacitor-based compensation systems.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">It is important to note that a detuned reactor is not a complete harmonic elimination solution. Where harmonic distortion exceeds acceptable limits, additional harmonic mitigation solutions such as Active Harmonic Filters or tuned passive filters may be required.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Industrial Applications of Detuned Reactor Harmonic Filters<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned reactors are commonly used in industrial environments where capacitor-based power factor correction systems operate alongside harmonic-generating equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Major application areas include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Automotive Industry:<\/strong> Manufacturing plants with VFDs, robotic systems, and automated production lines.<\/li>\n\n\n\n<li><strong>Iron and Steel Industry:<\/strong> Facilities operating induction furnaces, rolling mills, and heavy electrical equipment.<\/li>\n\n\n\n<li><strong>Textile Industry:<\/strong> Plants using variable-speed motors and industrial drives.<\/li>\n\n\n\n<li><strong>Cement Industry:<\/strong> Facilities with crushers, conveyors, and large motor-driven systems.<\/li>\n\n\n\n<li><strong>FMCG and Manufacturing:<\/strong> Production facilities with automated machinery, UPS systems, and electronic loads.<\/li>\n\n\n\n<li><strong>Commercial and Infrastructure Facilities:<\/strong> Large buildings and facilities with extensive electrical distribution and capacitor bank installations.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">How to Select the Right Detuned Reactor?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Selecting the right detuned reactor is important for ensuring capacitor bank protection and reliable power factor correction.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before choosing a reactor, the following parameters should be evaluated:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>System Voltage:<\/strong> The rated voltage of the electrical distribution network.<\/li>\n\n\n\n<li><strong>Capacitor Bank Rating:<\/strong> The kVAR rating and operating voltage of the capacitor bank.<\/li>\n\n\n\n<li><strong>Detuning Factor:<\/strong> The required detuning percentage based on system harmonic conditions.<\/li>\n\n\n\n<li><strong>Harmonic Spectrum:<\/strong> The magnitude and order of dominant harmonic components.<\/li>\n\n\n\n<li><strong>Operating Conditions:<\/strong> Load variations, ambient temperature, and installation environment.<\/li>\n\n\n\n<li><strong>System Compatibility:<\/strong> Compatibility with the existing APFC panel and electrical protection arrangement.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">A detailed <strong><a href=\"https:\/\/www.p2power.com\/power-quality-audit\/\" data-type=\"link\" data-id=\"https:\/\/www.p2power.com\/power-quality-audit\/\">Power Quality Audit<\/a><\/strong> and harmonic analysis can help determine the appropriate harmonic mitigation solution for a particular installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Harmonic distortion can significantly affect the performance and reliability of industrial electrical systems, particularly capacitor-based power factor correction installations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned Reactor Harmonic Filters provide an effective way to reduce the risk of harmonic resonance, protect capacitor banks, and improve the reliability of APFC panels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, selecting the right solution requires understanding the harmonic characteristics and operating conditions of the electrical network. Depending on the severity of harmonic distortion, facilities may also benefit from advanced solutions such as Active Harmonic Filters (AHF), Active Power Filters (APF), and Active Var Generators (SVG).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P2 Power Solutions<\/strong> provides advanced <strong><a href=\"https:\/\/www.p2power.com\/current-regulation\/\" data-type=\"link\" data-id=\"https:\/\/www.p2power.com\/current-regulation\/\">power quality solutions<\/a><\/strong> designed to address industrial electrical challenges. With solutions including Detuned Reactor Panels, Active Harmonic Filters, Active Var Generators, and Hybrid Power Factor Correction Systems, P2 supports industries in improving power quality, electrical reliability, and energy performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ&#8217;s<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. What is the main purpose of a detuned reactor?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The main purpose of a detuned reactor is to prevent harmonic resonance in power factor correction systems, protect capacitor banks from overheating, and improve the operational reliability of APFC panels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. How does a detuned reactor work in an APFC panel?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A detuned reactor is connected in series with each capacitor bank step. It changes the resonant frequency of the capacitor-reactor combination, helping prevent harmonic amplification and reducing the risk of capacitor failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. What is the difference between a detuned reactor and a harmonic filter?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A detuned reactor is generally used with capacitor banks to prevent resonance and reduce harmonic-related stress. A harmonic filter is a broader term that includes passive and active solutions designed to mitigate harmonic distortion in electrical systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Why are detuned reactors used in power factor correction systems?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned reactors are used in power factor correction systems to minimise harmonic resonance, protect capacitors, reduce the risk of equipment failure, and support reliable reactive power compensation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. What are the common applications of detuned reactor harmonic filters?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detuned reactor harmonic filters are commonly used in automotive, steel, cement, textile, pharmaceutical, FMCG, and other manufacturing industries where capacitor banks operate alongside non-linear electrical loads.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>6. Can a detuned reactor eliminate harmonics completely?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">No. A detuned reactor does not eliminate all harmonics. Its primary function is to prevent resonance and protect capacitor banks. Active Harmonic Filters or suitably designed passive harmonic filters may be required for effective harmonic reduction.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>7. What is the difference between a detuned reactor and an active harmonic filter?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A detuned reactor is a passive component used with capacitor banks to prevent harmonic resonance. An Active Harmonic Filter uses power electronics to dynamically compensate for harmonic currents generated by non-linear loads.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>8. What happens if an APFC panel operates without a detuned reactor?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In harmonic-rich electrical networks, an APFC panel without suitable detuning may experience resonance, excessive capacitor current, overheating, frequent capacitor failures, and reduced equipment life.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>9. How do I select the right detuned reactor for my capacitor bank?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Selection depends on the system voltage, capacitor bank kVAR rating, detuning percentage, harmonic spectrum, operating conditions, and system configuration. A power quality audit can help determine the appropriate reactor rating.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>10. Which industries require detuned reactor harmonic filters?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industries using VFDs, UPS systems, rectifiers, and other non-linear loads may require detuned reactors. Common examples include steel, automotive, textile, cement, manufacturing, and commercial infrastructure facilities.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Working, Benefits and Industrial Applications Harmonic distortion is one of the most common power quality challenges faced by modern industrial facilities. Non-linear electrical loads such as variable frequency drives (VFDs), UPS systems, rectifiers, and other power electronic equipment generate harmonics that can affect the performance, reliability, and efficiency of electrical networks. If left unmanaged, harmonics [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":157,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[77,128,73,76,71,129,127,131,74,72,130],"class_list":["post-151","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-quality-solutions","tag-active-power-filter-apf","tag-apfc-detuned-reactor","tag-de-tuned-reactors","tag-decoding-detuned-reactors","tag-detuned-reactor","tag-detuned-reactor-for-power-factor-correction","tag-detuned-reactor-for-apfc-panel","tag-detuned-reactor-in-capacitor-bank","tag-detuned-reactor-manufacturer","tag-what-is-detuned-reactor","tag-what-is-detuned-reactor-harmonic-filter-and-where-is-it"],"_links":{"self":[{"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/posts\/151","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=151"}],"version-history":[{"count":6,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/posts\/151\/revisions"}],"predecessor-version":[{"id":216,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/posts\/151\/revisions\/216"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=\/wp\/v2\/media\/157"}],"wp:attachment":[{"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=151"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=151"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.p2power.com\/featured-insights\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}